Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group
Lighting Systems EC1-2
Page 3 of 3 Energos Control System 2-Light T8 per 4' (121.92cm) (Nominal) Louver
C0808
Lamp Ordering Information
Design Lamp Type Wattage
Rated Output
(Lumens)
Color (K)
A T8 28 2725 3000
B T8 28 2725 3500
C T8 28 2725 4100
D T8 30 2850 3000
E T8 30 2850 3500
F T8 30 2850 4100
G T8 32 3000 3000
H T8 32 3000 3500
I T8 32 3000 4100
J T8 32 3100 3000
K T8 32 3100 3500
L T8 32 3150 4100
Ballast Ordering Information
Design Lamp Type Ballast Factor Start Type THD %
D T8 0.71 Program <10
E T8 0.88 Program <10
H Dim T8 1.00/.05 Program <10
Lamp and Ballast System Data
Design
Lamp Type
(T8 or T5)
Ballast
Factor (BF)
Ballast
THD (%)
Lamp Rated
Wattage
Lamp
Rated
Output
Lamp
Color
(Kelvin)
IES Output
(lumens)
System
Input
Watts
System
Efficacy
(lum/watt)
System
Lamp Life
(Hours)
Start
Type
DA T8 0.71 <10 28 2725 3000 2199 20.0 96.74 24000 Program
DB T8 0.71 <10 28 2725 3500 2199 20.0 96.74 24000 Program
DC T8 0.71 <10 28 2725 4100 2199 20.0 96.74 24000 Program
DD T8 0.71 <10 30 2850 3000 2299 21.5 94.12 24000 Program
DE T8 0.71 <10 30 2850 3500 2299 21.5 94.12 24000 Program
DF T8 0.71 <10 30 2850 4100 2299 21.5 94.12 24000 Program
DG T8 0.71 <10 32 3000 3000 2420 23.0 92.61 24000 Program
DH T8 0.71 <10 32 3000 3500 2420 23.0 92.61 24000 Program
DI T8 0.71 <10 32 3000 4100 2420 23.0 92.61 24000 Program
DJ T8 0.71 <10 32 3100 3000 2501 23.0 95.70 30000 Program
DK T8 0.71 <10 32 3100 3500 2501 23.0 95.70 30000 Program
DL T8 0.71 <10 32 3150 4100 2541 23.0 97.24 30000 Program
EA T8 0.88 <10 28 2725 3000 2725 25.5 94.04 24000 Program
EB T8 0.88 <10 28 2725 3500 2725 25.5 94.04 24000 Program
EC T8 0.88 <10 28 2725 4100 2725 25.5 94.04 24000 Program
ED T8 0.88 <10 30 2850 3000 2850 27.5 91.20 24000 Program
EE T8 0.88 <10 30 2850 3500 2850 27.5 91.20 24000 Program
EF T8 0.88 <10 30 2850 4100 2850 27.5 91.20 24000 Program
EG T8 0.88 <10 32 3000 3000 3000 29.0 91.03 24000 Program
EH T8 0.88 <10 32 3000 3500 3000 29.0 91.03 24000 Program
EI T8 0.88 <10 32 3000 4100 3000 29.0 91.03 24000 Program
EJ T8 0.88 <10 32 3100 3000 3100 29.0 94.07 24000 Program
EK T8 0.88 <10 32 3100 3500 3100 29.0 94.07 24000 Program
EL T8 0.88 <10 32 3150 4100 3150 29.0 95.59 24000 Program
HG T8 DIM 1.0 / 0.5 <10 32 2850 3000 2850 / 143 34 / 8 83.80 NA Program
HH T8 DIM 1.0 / 0.5 <10 32 2850 3500 2850 / 143 34 / 8 83.80 NA Program
HI T8 DIM 1.0 / 0.5 <10 32 2850 4100 2850 / 143 34 / 8 83.80 NA Program
Do not alter lumen values or ballast factor light losses when completing
calculations using Energos IES files. Files have already been adjusted. The lumen
value for the lamp (within a Lighting Design program) will be the IES Ouput value
shown on this table.
The lamp life table demonstrates the effects of shortened cycle-times with both
program start and instant start ballasts. The graph shows that instant ballasts
are susceptible to shortened lamp life if short cycle periods of less than 3 hours
are used. For cycle periods of greater than 3 hours program start ballast are not
required.
Lamp Life Table using program start and instant start ballasts.
*25°C Rating
All data is per 1 lamp on a two lamp system at 277 VAC.
Data is based on Osram Sylvania specifications.
When ordering no lamps provided by Lightolier, use lamp code “Z”.